Specifications

Chapter 5 Configuring a Typical Application Installation and Operation Manual
5-2 Connecting the Cables RICi-E3, RICi-T3 Ver. 1.0
5.2 Connecting the Cables
Connecting the Ethernet Port
To connect the Ethernet interface:
Connect the user LAN to the RJ-45 connector designated 10/100 BaseT.
Connecting the E3 or T3 Port
To connect the E3 or T3 interface:
1. Connect the Rx cable to the BNC designated Rx.
2. Connect the Tx cable to the BNC designated Tx
Connecting the Power
RICi-E3, RICi-T3 accept either 110-240 VAC or 48/60 VDC power through the
same power inlet.
Before connecting or disconnecting any cable, the protective earth terminals of
this unit must be connected to the protective ground conductor of the mains (AC
or DC) power cord. If you are using an extension cord (power cable) make sure it
is grounded as well.
Any interruption of the protective (grounding) conductor (inside or outside the
instrument) or disconnecting of the protective earth terminal can make this unit
dangerous. Intentional interruption is prohibited.
Connecting AC Power
AC power is supplied to the RICi-E3, RICi-T3 modem through a standard 3-prong
connector.
AC power should be supplied via a 1.5m (5 ft) standard power cable terminated
by a standard 3-prong connector. A cable is provided with the unit.
To connect AC power:
1. Connect the power cable to the power connector on the RICi-E3, RICi-T3 rear
panel.
2. Connect the power cable to the mains outlet.
The unit will be turned on automatically upon connection to the mains.
Warning