Specifications

Chapter 4 Configuration Installation and Operation Manual
4-20 Additional Tasks RICi-E3, RICi-T3 Ver. 1.0
To access the Monitoring menu:
From the Main menu, select Monitoring.
The Monitoring menu appears as illustrated in
Figure 4-18
.
RICi-E3, RICi-T3
Monitoring
1. System >
2. Physical Ports >
3. Applications >
>
ESC-prev menu; !-main menu; &-exit; 1 user(s)
Figure 4-18. Monitoring Menu
Displaying System Status Information
System menu specifies MAC address of the RICi-E3, RICi-T3 unit and provides
access to the information on the interface connection status. For description of
RICi-E3, RICi-T3 system messages, which are displayed via the Log File screen,
refer to
Chapter 5
.
To display interface connection information:
1. Navigate to Main Menu > Monitoring > System > Connection Status.
The Connection Status screen appears as illustrated in
Figure 4-19
for E3
and
Figure 4-20
for T3 respectively.
RICi-E3
Monitoring>System>Connection Status
Index Description Type Status Operation Speed
1 ETHERNET PORT Fast Eth copper Up Up 100000000
2 E3 PORT DS3 Up Up 34368000
r – Refresh Table
ESC-prev menu; !-main menu; &-exit; ?-help
Figure 4-19. E3 Connection Status Screen
The Connection Status screen includes the following information:
Description – ETH (User) or E3/T3 (Network) interfaces
Type – type of the interface according to the INF TYPE MIB
Status – administrative status of the link (Up or Down), as set via the
Ethernet as illustrated in
Figure 4-9
, and E3/T3 a illustrated in
Figure 4-10
and
Figure 4-11
respectively.
Operation –current operational status of the link (Up or Down).