Specifications

Chapter 4 Configuration Installation and Operation Manual
4-14 Configuring for Operation RICi-E3, RICi-T3 Ver. 1.0
Configuring the T3 Port
RICi-T3 includes a T3 port. You can configure its parameters at the physical level
as follows:
To configure the T3 port:
1. From the Physical Ports menu, select T3.
The T3 menu appears as illustrated in
Figure 4-11
.
RICi-T3
Configuration > Physical Ports >T3
1. Administrative Status (Up)
2. Framing (M23)
3. Tx Clock (LBT)
4. Line Build Out (Up to 225ft)
5. Protocol (LAPS)
ESC-prev menu; !-main menu; &-exit 1 user(s)
Figure 4-11. T3 Menu
2. From the T3 menu, configure the following:
Administrative Status
Up – the network port is enabled
Down – the network port is disabled.
Framing. Specifies the framing type
M23
C-bit.
Tx Clock. Specifies the clock
Internal Clock
LBT.
Line Build Out for Line Mode = DSU. The length of a cable in feet between
T3 port connector and the network access point
Up to 225 feet – 0 to 225 ft
Over 225 feet – 225 ft and further.
Protocol. Specifies the encapsulation
HDLC
LAPS.
3. Select Save to complete the user T3 port configuration.
The selected value shows in the T3 Port configuration menu.