Instruction manual

Quick Start Guide RIC-E3/ETH, RIC-T3/ETH Installation and Operation Manual
2 Operating RIC-E3/ETH and RIC-T3/ETH
Configuring the Ethernet Interface
Configure the Ethernet interface according to the tables below:
Section Name Description Possible Settings Factory Setting
1 NC OFF
2 FLC Enables or disables flow
control
ON – Flow control is enabled
OFF – Flow control is disabled
OFF
3 10/100 Selects the LAN speed
ON – LAN speed is 100 Mbps
OFF – LAN speed is 10 Mbps
OFF
4 AN1 Controls the LAN
autonegotiation
ON – LAN autonegotiation is disabled
OFF – LAN autonegotiation is enabled
OFF
5 HF1 Selects the LAN mode ON – LAN full duplex mode
OFF – LAN half duplex mode
OFF
6 BPR Controls the backpressure
ON
– Backpressure is enabled
OFF – Backpressure is disabled
OFF
7 MUL Controls LAN to WAN
multicasting
ON – Multicast messages from LAN to
WAN are blocked
OFF
– Multicast messages from LAN
to WAN are not blocked
OFF
8 SCR Controls the scrambling of
Ethernet frames
ON – Ethernet frames are scrambled
OFF
– Ethernet frames are left
unchanged
OFF
Connecting the Cables
To connect cables:
1. Connect the E3 or T3 electrical interface.
2. Connect the Ethernet interface to the LAN.
3. Connect the power cable (first to the converter, then to the mains supply).
2. Operating RIC-E3/ETH and RIC-T3/ETH
Verify LED status:
The PWR LED should be ON.
The LINK and ACT LEDs should be ON, when the link to the LAN is
established, and data is transferred over the Ethernet link.
The ETH 100 LED is ON when the converters work in the 100 Mbps mode.