Specifications

Chapter 2 - Installation and Setup FLM-1
Installation & Operation Manual
2-6 Installation and Setup 16/01/01 11:12 AM
RJ-45 Connectors
Twelve RJ-45 modular jacks on the rear panel (see Figures 2-5 to 2-7)
each support a single channel. Pinout for this option is given in
Appendix B.
The six-channel operation with full duplex data and transmitting control
signals end-to-end requires special cables (not provided by RAD).
Figure 2-11 shows suggested pin connections for transmitting a
DTR-to-DSR control signal and Figure 2-12 those for transmitting an
RTS-to-DCD control signal.
Protective Ground
Transmitted Data (TD)
Received Data (RD)
Request to Send (RTS)
Clear to Send (CTS)
Data Set ready (DSR)
Received Line Signal Detector
Signal Ground
1
5
3
2
8
6
4
7
5
3
n/c
n/c
n/c
n/c
n/c
n/c
5
3
n/c
n/c
n/c
n/c
n/c
n/c
1
5
3
2
8
6
4
7
1
2
3
4
5
6
8
20
7
FLM-1
Subchannel
Connector
Channel Data and
Control Connection
Special Cable 1
(DB-25)
Secondary TD
Secondary RD
Channels 1-6
Channels 7-12
Figure 2-11 Suggested Connection for Transmitting DTR to DSR Control Signals End-to-End
(RJ-45 Connectors)
1
2
3
4
5
6
7
8
5
3
n/c
n/c
n/c
n/c
n/c
n/c
1
5
3
2
8
6
4
7
Channel Data and
Control Connection
Special Cable 2
(DB-25)
Protective Ground
Transmitted Data (TD)
Received Data (RD)
Request to Send (RTS)
Clear to Send (CTS)
Data Set ready (DSR)
Received Line Signal Detector
Signal Ground
1
5
3
2
8
6
4
7
5
3
n/c
n/c
n/c
n/c
n/c
n/c
FLM-1
Subchannel
Connector
Secondary TD
Secondary RD
Channels 1-6
Channels 7-12
Figure 2-12 Suggested Connection for Transmitting RTS to DCD Control Signals End-to-end
(RJ-45 Connectors)