FLM-1 6/12 Port Fiber-Optic Multiplexer Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications. No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications. No representation or warranties for fitness for any purpose other than what is specifically mentioned in this manual is made either by RAD Data Communications or its agents.
Warranty This RAD product is warranted against defects in material and workmanship for a period of one year from date of shipment. During the warranty period, RAD will, at its option, either repair or replace products which prove to be defective. For warranty service or repair, this product must be returned to a service facility designated by RAD. Buyer shall prepay shipping charges to RAD and RAD shall pay shipping charges to return the product to Buyer.
Safety Warnings The exclamation point within a triangle is intended to warn the operator or service personnel of operation and maintenance factors relating to the product and its operating environment which could pose a safety hazard. Always observe standard safety precautions during installation, operation and maintenance of this product. Only a qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this instrument.
Declaration of Conformity Manufacturer’s Name: RAD Data Communications Ltd. Manufacturer’s Address: 24 Raoul Wallenberg St. Tel Aviv 69719 Israel declares that the product: Product Name: FLM-1 Conforms to the following standard(s) or other normative document(s): EMC: EN 55022 (1994) Limits and methods of measurement of radio disturbance characteristics of information technology equipment.
Contents CHAPTER 1 INTRODUCTION 1.1 Overview ....................................................................................................................... 1-1 General ................................................................................................................................ 1-1 Versions................................................................................................................................ 1-1 Applications.................................................
Contents CHAPTER 4 TROUBLESHOOTING AND DIAGNOSTICS 4.1 Frequently Asked Question ............................................................................................ 4-1 4.2 Diagnostics Tests ............................................................................................................ 4-1 Local Loopback..................................................................................................................... 4-2 Remote Loopback...............................................
List of Figures Figure 1-1 Typical Point-to-Point Application................................................................................ 1-2 Figure 1-2 Typical Ring Installation ............................................................................................... 1-2 Figure 1-3 FLM-1 3D View ........................................................................................................... 1-3 Figure 2-1 Strapping Diagram ...............................................................
List of Tables iv FLM-1 Installation and Operation Manual
Chapter 1 Introduction 1.1 Overview General FLM-1 is a full duplex time division asynchronous multiplexer enabling up to twelve async terminals to be multiplexed onto a single channel. FLM-1 is intended for use in manufacturing facilities, building complexes, campuses and other similar point-to-point and ring applications.
FLM-1 Installation & Operation Manual Chapter 1 - Introduction Figure 1-1 Typical Point-to-Point Application Ring Application For installations involving clusters of terminals distributed in several locations, FLM-1 units may be installed in a ring-type configuration, as shown in Figure 1-2.
FLM-1 Installation & Operation Manual Chapter 1 - Introduction Table 1-1 shows distortion per node and maximum number of nodes/sites allowed for different data rates on each subchannel, for the 4-wire and the dual-fiber versions. Table 1-1 Distortion and Number of Sites for FLM-1 in Ring Application Data Rate (kbps) Distortion per Node (%) Number of Nodes/Sites 4 wire Fiber 4 wire Fiber 19.2 25.00 12.50 2 4 9.6 12.50 6.250 3 4 4.8 6.250 3.125 4 8 2.4 3.125 1.5625 8 16 1.2 1.
FLM-1 Installation & Operation Manual Chapter 1 - Introduction Front Panel The front panel provides control over the operation of the unit. The LEDs provide real-time indications related to the operation and status of the unit. Two push-button switches allow test loopbacks for the FLM-1 diagnostics. For details, see Chapter 3, “Operation” and Chapter 4, “Troubleshooting and Diagnostics”. Rear Panel The rear panel of the unit allows access to interface and power connections.
FLM-1 Installation & Operation Manual Note Chapter 1 - Introduction 1. The distortion refers to the duty cycle and not to the voltage level. 2. Whenever possible (if the number of channels is less than or equal to 6) it is recommended to operate FLM-1 in the six-channel mode, which results in less distortion. 1.4 Technical Specifications Subchannels Transmission format Asynchronous Data rate Optical interface: up to 38.4 kbps Electrical interface: up to 19.
FLM-1 Installation & Operation Manual Chapter 1 - Introduction Optical Interface Transmission line Double optical cable Operating range for 850 nm: up to 5 km (3.1 miles) for 1300 nm: up to 40 km (25 miles) with attenuation of of 0.5 dB/km with 9/125µ fiber optic cable Data rate 2.4576 Mbps Operating wavelength 850 nm or 1300 nm Optical output level Diagnostics Switches and Indicators 1-6 for 850 nm: -24 dBm min into 50/125 fiber -20 dBm min into 62.
FLM-1 Installation & Operation Manual Chapter 1 - Introduction Power 100/115/230 VAC (± 10%), 50-60 Hz, 7.5 VA Max Physical Height 4.4 cm / 1.72 in (1U) Width 33.8 cm / 13.30 in Depth 22.0 cm / 8.60 in Weight 1.6 kg / 3.
Chapter 1 - Introduction 1-8 Technical Specifications FLM-1 Installation & Operation Manual 16/01/01 11:12 AM
Chapter 2 Installation and Setup 2.1 Introduction This chapter provides instructions for mechanical and electrical installation of FLM-1. Sections 2.2 and 2.3 describe site preparation for installation of FLM-1. Section 2.4 describes mechanical and electrical installation, including strap selection, setting the internal jumpers, connecting the main link and subchannel interfaces and connecting the power.
Chapter 2 - Installation and Setup FLM-1 Installation & Operation Manual 2.4 Installation and Setup The FLM-1 units are delivered completely assembled. The units are designed for desktop installation or mounting in a 19-inch rack. Installation procedures for the FLM-1 unit are provided in the following paragraphs. For rack installation of FLM-1, refer to the Rack Mounting Kit for 19-inch Racks guide that comes with the RM kit.
FLM-1 Installation & Operation Manual Chapter 2 - Installation and Setup GND 32 NC 12 SELECT 6 OR 12 6 CHANNELS J1 Figure 2-1 Strapping Diagram Connecting the Interfaces Figure 2-2 to Figure 2-7 show the FLM-1 rear panel in all its versions, containing different main link and subchannel connectors. Figure 2-2 to Figure 2-4 show the FLM-1 versions with DB-25 subchannel connectors and different main link connectors: terminal block, RJ-45, and dual fiber.
FLM-1 Installation & Operation Manual Chapter 2 - Installation and Setup MAIN SUBCHANNELS CHANNEL 1 2 3 4 5 6 7 8 9 10 11 12 115 VAC 0.2A T 250V Figure 2-5 FLM-1/4W Rear Panel with RJ-45 Main Link and Subchannel Connectors MAIN CHANNEL SUBCHANNELS 1 2 3 4 5 6 7 8 9 10 11 12 115 VAC 0.2A T 250V RX TX Figure 2-6 FLM-1/DF Rear Panel with STA Main Link and RJ-45 Subchannel Connectors MAIN CHANNEL RX-B RX-A SUBCHANNELS TX-B TX-A 1 115 VAC 0.
FLM-1 Installation & Operation Manual Chapter 2 - Installation and Setup FLM-1 Subchannel Connector Channel Doubler Cable Port A 1 2 3 4 5 6 8 15 17 20 24 7 Protective Ground Transmitted Data (TD) Received Data (RD) Request to Send (RTS) Clear to Send (CTS) Data Set Ready (DSR) Received Line Signal Detector Not Used Signal Ground 1 2 3 4 5 6 8 15 17 20 24 7 1 2 3 4 5 6 8 15 17 20 24 7 Port B 14 16 19 13 21 12 11 18 25 23 Secondary TD Secondary RD Secondary RTS Secondary CTS Secondary DSR Secondary
FLM-1 Installation & Operation Manual Chapter 2 - Installation and Setup RJ-45 Connectors Twelve RJ-45 modular jacks on the rear panel (see Figures 2-5 to 2-7) each support a single channel. Pinout for this option is given in Appendix B. The six-channel operation with full duplex data and transmitting control signals end-to-end requires special cables (not provided by RAD).
FLM-1 Installation & Operation Manual Chapter 2 - Installation and Setup Connecting the Main Channel 4-wire Version - Terminal Block A 5-screw terminal block is located at the rear panel (see Figures 2-2 and 2-7). Five wires, marked TX-A, TX-B, RX-A, RX-B and CHASSIS GND connect transmit and receive wires and the cable shield (if available). To connect the main link with the terminal block, proceed as follows: 1. Connect TX connectors at the local unit to RX connectors at the opposite unit. 2.
Chapter 2 - Installation and Setup Warning FLM-1 Installation & Operation Manual Before connecting power to the unit, verify that the socket outlet is provided with a protective earth contact. If you are using an extension cord (power cable) make sure it is grounded as well. Interrupting the protective (grounding) conductor (inside or outside the unit), or disconnecting the protective earth terminal can make this unit dangerous.
Chapter 3 Operating Instructions 3.1 General This chapter covers: • A list of controls and indicators together with their functions. • An operating procedure covering power turn-on, operating instructions, and power turn-off. • Information on strapping. Before operating FLM-1, complete all the installation procedures described in Chapter 2. 3.2 Front Panel Indicators and Switches The FLM-1 front panel is shown in Figure 3-1.
FLM-1 Installation & Operation Manual Chapter 3 - Operation Table 3-1 lists the functions of the FLM-1 indicators and switches. Table 3-1 FLM-1 Indicators and Switches Identification No Name Type Function 1 POWER LED Indicator (green) Lights up when the unit is powered. 2 TEST LED Indicator (yellow) Lights up when either local or remote unit is performing a loopback test. 3 SYNC LOSS LOCAL LED Indicator (red) Lights up when synchronization is lost at the local unit.
Chapter 4 Troubleshooting and Diagnostics 4.1 Frequently Asked Question Question: How can I connect six pairs of DTEs for transferring Data and Control Signals (RTS to DCD) end-to-end? Answer: First set the jumper marked “SELECT 6 OR 12 CHANNELS” to the “12” position. Now FLM-1 passes 12 pairs of signals (TD and RD of channels 1 to 6 and secondary TD and RD of channels 7 to 12) end-to-end.
Chapter 4 - Troubleshooting and Diagnostics Local Loopback FLM-1 Installation & Operation Manual When FLM-1 performs a local loopback, the data from the local transmitter is looped back to the local receiver at the digital level, thus checking all local digital circuitry for proper operation. To activate the test, press the LLB push button located on the front panel. If the local unit is operating properly, the yellow TEST indicator should light up and all other indicators should be OFF.
FLM-1 Installation & Operation Manual Chapter 4 - Troubleshooting and Diagnostics Table 4-1 Fault Isolation and Troubleshooting Symptom All front panel indicators are OFF Action 1. Check that power is supplied to the unit. 2. Check the fuse inside the AC receptacle on the rear panel and replace it with a new one. 3. Replace the unit. The fault is probably in the unit's power supply circuits. LOCAL SYNC LOSS LED is ON 1. Perform an LLB test as described in Section 4-1.
Chapter 4 - Troubleshooting and Diagnostics 4-4 Fault Isolation and Troubleshooting FLM-1 Installation & Operation Manual 09/01/01 4:29 PM
Appendix A Pin Assignment for Subchannels with DB-25 Connectors Table A-1 Pin Assignment for Subchannels with DB-25 Connectors V.24 RS-232 Pin Signal Description 101 AA 1 Protective Ground Chassis ground. May be isolated from signal ground (see Section 2-4). 102 AB 7 Signal Ground Common signal and DC power supply ground. 103 BA 2 (14) TD - Transmit Data Serial digital data into FLM-1, end-to-end. 104 BB 3 (16) RD - Receive Data Serial digital data output from FLM-1, end-to-end.
Appendix A - Pin Assignment for Subchannels with DB-25 Connectors A-2 FLM-1 Installation & Operation Manual 09/01/01 4:29 PM
Appendix B Pinout for RJ-45 Connectors The pinouts of the RJ-45 connectors for the FLM-1 line (main channel) and subchannels are given in Tables B-1 and B-2, respectively.
Appendix B - Pinout for RJ-45 Connectors B-2 FLM-1 Installation & Operation Manual