1. Bring the cursor under the leftmost field in the top row (if not already there)
2. Scroll to display SYSTEM PARAMETER in the top row
Second row shows the first system parameter, CLK MASTER, and its
current selection
3. Bring the cursor under the left-hand field in the second row.
4. Scroll to see the other system parameters.
After each time SCROLL is pressed the second display row shows the
current value of the next system parameter. Continue until CLK MASTER
appears again.
5. Bring the CURSOR under the leftmost field in the top row.
6. Scroll to display the next group of configuration parameters, LINK PARAM.
7. Bring the cursor under the rightmost field in the top row, and scroll to display
ML (main link).
The second row shows the first main link parameter, FRAME, and its
current value.
8. Repeat steps 3, 4 to see the other main link parameters.
After each time SCROLL is pressed, the second row shows the current value
of the next main link parameter. Continue until FRAME appears again.
9. For FCD-E1 versions with a sublink, bring the cursor under the rightmost field
in the top row, and scroll to display SL (sublink).
The second row shows the first sublink parameter, FRAME, and its current
value.
10. Repeat steps 3, 4 to see the other sublink parameters.
After each SCROLL pressing, the second row shows the current value of
the next sublink parameter. Continue until FRAME appears again.
When displaying the sublink timeslot assignment in the USER mapping mode, the
second row includes a timeslot number field (in the middle of the row). To display
the selections made for each timeslot, move the cursor under this field and scroll.
11. Repeat steps 1 through 4 to display the supervisory port parameters, SP PARAM.
12. Repeat steps 5 through 8 to display the channel 1 parameters, CHANNEL PRM
CH1.
13. For the FCD-E1 versions with two data ports, or with an Ethernet interface,
repeat steps 6, 7, 8 to display the parameters for channel 2 (serial or Ethernet
interface), CHANNEL PRM CH2.
Repeat steps 1 through 4 to display the download parameters, DNLOAD PRM.