Unit installation

Chapter 4 Configuration Installation and Operation Manual
4-2 Introduction FCD-E1
4.2 Introduction
FCD-E1 operating mode is determined by a set of parameters stored in an internal
non-volatile memory. You select these parameters, using the FCD-E1 front panel
push buttons, a supervision terminal, or a network management station (either a
generic SNMP management station, or the RADview management station offered
by RAD). When a supervision terminal, or a network management station is in
control, the FCD-E1 cannot be controlled from the front panel; however, when
under the control of a network management station, the front panel can still be
used to read the current parameters, status, and statistics.
The FCD-E1 has six groups of configuration parameters:
System parameters
Main link parameters
Sublink parameters
Channel parameters
Supervisory port parameters
Download parameters.
In addition to the parameters configured from the front panel, there are
parameters that can be controlled only from a supervision terminal or remote
management station. These are presented in Appendix D.
After configuration, if alarm messages are stored in its ALARM BUFFER, the
FCD-E1 automatically returns to the display of status messages.
After the operating parameters have been selected, a process called configuration
set-up is performed and the FCD-E1 no longer requires operator attendance. The
configuration stored in the FCD-E1 memory is not affected when power is turned
off.
Upon turn-on, the FCD-E1 checks the validity of the stored configuration data, and
if everything is OK, it assumes the last selected configuration.
If the configuration does not require modification, the FCD-E1 is then ready
for operation immediately after power is applied.
If the configuration data is not valid, the FCD-E1 lets you load instead a default
configuration. The default configuration, prepared by the manufacturer, is
stored in the program EPROM.
Configuration and Management Activities
Before an FCD-E1 system can be used in its intended application, it is necessary to
perform two types of activities:
Preliminary configuration, which prepares the FCD-E1 system for using any
of the management facilities supported by the system.
The preliminary configuration of the FCD-E1 system must always be
performed using an ASCII terminal equipped with an RS-232 communication
interface, directly connected to the FCD-E1 supervisory port (the CONTROL
DCE connector).