Unit installation
Installation and Operation Manual Chapter 3 Operation
FCD-E1 Local Configuration Setup Procedure 3-11
To set up the FCD-E1 configuration:
1. Select the system parameters.
2. Select the main link parameters.
3. Select the sublink parameters.
4. Select the channel parameters.
5. Select the supervisory port parameters (if FCD-E1 is going to be controlled via
a terminal).
6. Select the download parameters (to enable inband management).
FCD-E1 presents only those parameters available in the selected mode; therefore it
is important to perform the configuration according to the order specified above.
Before starting the configuration procedure, always disconnect all the user-initiated
loopbacks (select OFF on TEST OPTIONS). If you try to configure while a
user-initiated loopback is active, the CONFIG ERROR 008 message is displayed.
Refer to Configuration Error Messages on page 6-3 for an explanation of the
configuration error messages the FCD-E1 displays when you make an error.
To configure the FCD-E1 unit:
1. Bring the cursor under the leftmost field in the top row (if not already there).
2. Scroll to display the desired group of parameters in the top row; the second
row shows the first parameter in the selected group and its current value.
When the desired group of parameters must be separately selected for each link
and/or data channel, the top row includes an additional field (at the rightmost side
of the top row): this field is used to select the link type (main or sub), respectively
the channel number. In this case, use the CURSOR key to bring the cursor to the
link or channel field, then SCROLL to show the desired link or channel.
3. Bring the cursor under the leftmost field (parameter name) in the second row.
4. Scroll to display the desired parameter in the selected group. For certain
parameters, for example timeslots, an additional field located in the left-hand
field of the second row is used to select an individual item; the second row
shows the parameter name and its current value.
5. Bring the cursor to the right-hand field (parameter name) in the second row.
6. Scroll to set the required value for the displayed parameter; the right-hand
field in the second row shows the available values.
7. When the desired parameter value is displayed, select the new parameter
value by pressing ENTER; the cursor remains on the right-hand field of the
second row. The second row displays shortly CONFIG ENTER, then returns to
the normal display.
You must press ENTER after changing parameters of a certain group, such as
SYSTEM, CH1, etc. If you change parameter values, but return the cursor to the first
field of the first row and scroll to another group without pressing ENTER, the
changes are discarded and you will see the message CONFIG LOST.
Not
e
Not
e
Not
e