Unit installation

Installation and Operation Manual Chapter 3 Operation
FCD-E1 Configuration Alternatives 3-7
7. Bring the cursor under the rightmost field in the top row, and scroll to display
ML (main link).
The second row shows the first main link parameter, FRAME, and its
current value.
8. Repeat steps 3, 4 to see the other main link parameters.
After each time SCROLL is pressed, the second row shows the current value
of the next main link parameter. Continue until FRAME appears again.
9. For FCD-E1 versions with a sublink, bring the cursor under the rightmost field
in the top row, and scroll to display SL (sublink).
The second row shows the first sublink parameter, FRAME, and its current
value.
10. Repeat steps 3, 4 to see the other sublink parameters.
After each SCROLL pressing, the second row shows the current value of
the next sublink parameter. Continue until FRAME appears again.
When displaying the sublink timeslot assignment in the USER mapping mode, the
second row includes a timeslot number field (in the middle of the row). To display
the selections made for each timeslot, move the cursor under this field and scroll.
11. Repeat steps 1 through 4 to display the supervisory port parameters, SP PARAM.
12. Repeat steps 5 through 8 to display the channel 1 parameters, CHANNEL PRM
CH1.
13. For the FCD-E1 versions with two data ports, or with an Ethernet interface,
repeat steps 6, 7, 8 to display the parameters for channel 2 (serial or Ethernet
interface), CHANNEL PRM CH2.
14. Repeat steps 1 through 4 to display the download parameters, DNLOAD PRM.
3.4 Configuration Alternatives
This section presents information regarding the connection of a management
facility (supervision or alarm monitoring terminal, Telnet host, SNMP network
management station, etc.) to an FCD-E1 system.
In addition to the information presented in this section, FCD-E1 also supports
management by a remote facility. The facility can be connected to another RAD
equipment unit (e.g., MEGAPLEX and MAXcess multiplexers, DXC multiservice
access nodes, FCD-E1 and FCD-T1 fractional E1, respectively T1, integrating
multiplexers, etc.) that is connected to one of the FCD-E1 links (this management
method is called inband management). Specific information regarding inband
management is presented in the SNMP Management appendix.
Not