Unit installation

Chapter 3 Operation Installation and Operation Manual
3-6 Default Settings FCD-E1
Ethernet Interface Indications
For information concerning the IR-ETH and IR-ETH/Q interface indicators, refer to
Appendix E and Appendix F, respectively
3.3 Default Settings
If the configuration data stored by FCD-E1 is corrupted, the DB CHKSUM ERR
alarm message is generated. In this case, you will have to load the default
configuration.
To load the default configuration:
1. Turn FCD-E1 off.
2. Set section 3 of the internal switch S1 to ON.
3. Turn FCD-E1 on.
4. Turn FCD-E1 off.
5. Set section 3 of the internal switch S1 to OFF.
You can verify the FCD-E1 configuration as explained below. If the configuration
does not require modification, the FCD-E1 is ready for operation immediately after
self-test is completed. To change the configuration, refer to the Local Configuration
Setup Procedure below.
Checking Current Operating Configuration
This section provides instructions for displaying the current configuration
parameters (diagnostic and test functions are not included). The instructions are
presented in a step-by-step format that will help you familiarize with the use of
front panel push buttons. You may also refer to the menu structure shown in
Figure 3-2 for navigation.
During the following procedure, do not press the ENTER push button, to prevent
accidental change of parameters.
1. Bring the cursor under the leftmost field in the top row (if not already there)
2. Scroll to display SYSTEM PARAMETER in the top row
Second row shows the first system parameter, CLK MASTER, and its
current selection
3. Bring the cursor under the left-hand field in the second row.
4. Scroll to see the other system parameters.
After each time SCROLL is pressed the second display row shows the
current value of the next system parameter. Continue until CLK MASTER
appears again.
5. Bring the CURSOR under the leftmost field in the top row.
6. Scroll to display the next group of configuration parameters, LINK PARAM.
Not