Unit installation

Installation and Operation Manual Chapter 2 Installation and Setup
FCD-E1 Setting the Internal Jumpers and Switches 2-11
Table 2-1. Main Link Jumper and Switch Settings (Cont.)
Function Jumper or
Switch
Description Values (Default value in bold)
Section 3 -
DB INIT
This section selects the source
of the data base configuration
parameters.
OFF – On power-up, FCD-E1
loads the user-selected
parameters from its non-volatile
memory.
ONOn power-up, FCD-E1
loads the default parameters
stored in its program EPROM.
User-selected parameter values are not erased by
setting one or more switch sections to ON: this
action merely causes the FCD-E1 to use the
default values. However, if the FCD-E1 is turned
off and then powered up again, the default values
replace the user values.
Section 4 -
PC/SP
This section is not used, and
must always be set to OFF.
OFF
Jumpers JP2, JP68 and Interface changers RS-422/X.21, RS-422, X.21, and V.35 are
permanently set at the factory. Do not move these jumpers from their factory
positions!