Unit installation

Installation and Operation Manual Chapter 1 Introduction
FCD-E1 Technical Specifications 1-31
Dial-in capabilities
(CONTROL DCE
port)
Supports all the supervisory port functions
Dial-out capabilities
(CONTROL DTE and
CONTROL DCE
ports)
Event-activated; can control a dial-up
(Hayes-compatible) modem to dial a pre-programmed
number in case of an alarm event
Alarm Buffer
Alarm buffer size: 100 alarms
Alarm Relay
Three pins available on the CONTROL DTE port.
Function
Floating change-over contacts
Contact Ratings
Open contacts: maximum 60 VDC
Closed contacts: maximum 1A
Controls
Liquid Crystal
Display
2 rows of 16 characters
Push Buttons
CURSOR, SCROLL, ENTER
Front Panel
Indicators
SYNC LOSS LOC: Loss of local synchronization alarm on
the main link (MAIN) and sublink (SUB) (red)
SYNC LOSS REM: Loss of remote synchronization alarm
on the main link (MAIN) and sublink (SUB) (red)
TEST: test active (yellow)
ALARM: alarm indication (red)
Rear Panel Ethernet
Interface Indicators
For the IR-ETH and IR-ETH/Q interfaces, refer to
Appendix E and Appendix F, respectively.
Physical
Characteristics
Height
4.37 cm / 1.7 in (1U)
Width
21.5 cm / 8.5 in
Depth
24.3 cm / 9.5 in
Weight
1.3 kg / 2.9 lb
Power
Requirements
Supply Voltage
AC Source
100 to 240 VAC, 50/60 Hz
DC Source
–48 VDC nominal (–40 to –57 VDC)
Power Consumption
10W
Environment
Operating
Temperature
0° to 50°C / 32° to 122°F
Relative Humidity
Up to 90%, non-condensing