Unit installation

Installation and Operation Manual Appendix D Command Language
FCD-E1 Supervisory Terminal Commands D-45
Table D-14. FCD-E1 Default Configuration Used with Supervision Terminal (Cont.)
Type Parameter Designation Default Value
Data Channels MULTIPLIER
SPEED
FIFO SIZE
CLK_MODE
CTS
MAP_MODE
START_TS
TS_TYPE
Timeslot Map Type (USER
mode only)
ETHERNET MODE
BRIDGING
64
NC
AUTO
DCE
ON
USER
N/A
N/A
NC
HALF
FILTER
SP (Supervisory Port) SPEED
DATA
PARITY
INTERFACE
CTS
DCD_DEL
DSR
POP_ALM
PWD
LOG_OFF
AUXILIARY_DEVICE
AUTO
8
NO
DCE
=RTS
0_MS
ON
NO
NO
NO
TERMINAL
DP (Dial-out Port) SPEED
DATA
PARITY
CALL_OUT_MODE
9600 bps
8
NO
NONE
Download DNLOAD MODE NONE
BERT PATTERN
ERROR_INJECTION_RATE
RX_INBAND
2E3-1
NO ERR
DISABLE
LOOP
Purpose
Activate the specified user-initiated test or loopback.
A remote loopback cannot be activated when a local loopback is already
connected, and vice versa. In such case, you will see ERROR 051 (illegal port loop
configuration).
Syntax
LOOP {‘loopback’}
Note