DEF SYS
Purpose
Define the system parameters. Refer to Table D-1 for the parameter description,
allowable ranges and configuration guidelines.
Syntax
DEF SYS
Use
1. To define the FCD-E1 system parameters, type:
DEF SYS<Enter>
The system parameters data form is displayed. A typical form is shown
below.
CLK_MASTER CLK_FBACK DATE_FORMAT
INT NONE YYYY-MM-DD
2. After the desired parameter values are selected, press <Enter> to end.
Table D-12 describes additional system parameter available only through the
supervisory terminal.
Table D-12. Additional System Parameter
Parameter Function Values
DATE_FORMAT
Selects the date display format The available selections are DD/MM/YYYY, and
MM/DD/YYYY or YYYY-MM-DD.
Default: YYYY-MM-DD
DEF TERM
Purpose
Define the control codes for use with one of the following types of terminals:
TV920, VT52, VE100, Freedom 100/110 or Freedom 220, or reset the codes to 0.
If you are using a different type of terminal, use the F command to define the
desired codes.
The codes used by the above-mentioned terminals are listed in Table D-13.
Table D-13. Supervision Terminal Control Codes
Function Terminal Type
TV920 VT52 VT100 Freedom 100/110 Freedom 220
Clear Screen 1B2A0000 N/A 1B5B324A 1B2A0000 1B5B324A
Cursor Home 1E000000 1B480000 1B5B4800 1E000000 1B5B4800
Cursor Right 0C000000 1B424000 1B5B3143 0C000000 1B5B0143