Unit installation

Installation and Operation Manual Appendix D Command Language
FCD-E1 Supervisory Terminal Commands D-31
Table D-11. Additional Supervisory Port Parameters
Parameter Function Values
CTS
Controls the state of the CTS line in
the CONTROL DCE port
ON – The CTS line is always ON (active)
=RTS – The CTS line follows the RTS line.
Default: =RTS
DCD_DEL
With the CONTROL DCE port
defined as DTE, indicates the delay
(in msec) between DCD=ON and
sending of data
The available values are 0, 10, 50, 100, 200,
and 300 msec. If you select a non-zero
value when the port interface is
programmed as DCE, you will receive
ERROR 004 (illegal DCD_DEL and interface
combination).
Default: 0
DSR
Controls the state of the DSR line ON – The DSR line is continuously on. It
will switch to OFF for five seconds after the
DTR line is switched OFF. If you select
DSR=ON when INT=DTE, you will receive
ERROR 005 (conflict in interface and DSR
parameters)
=DTR – The DSR line tracks the DTR line.
Default: ON
POP_ALM
Controls the automatic sending of
alarms to a terminal connected to the
CONTROL DCE port
YES – The terminal automatically displays
every 10 minutes the alarm status (or
whenever an alarm which is not masked
using the DEF ALM MASK command
changes to ON).
NO – The automatic display feature is
disabled.
Default: NO
PWD
Controls password protection YES – Password protection enabled.
NO – Password protection disabled.
Default: NO
LOG_OFF
Controls the idle disconnect time of
the CONTROL DCE port
NO – Automatic session disconnection
disabled. To disconnect the session, use the
BYE command.
3_MIN – Automatic disconnection after
three minutes if no input data is received by
the CONTROL DCE port.
10_MIN – Automatic disconnection after
10 minutes if no input data is received by
the CONTROL DCE port.
Default: NO