Unit installation
Installation and Operation Manual Appendix D Command Language
FCD-E1 Supervisory Terminal Commands D-25
Use
1. To define the dial-out port communication parameters type:
DEF DP<Enter>
The dial-out port parameters data form is displayed. A typical form is
shown below.
SPEED DATA PARITY CALL_OUT_MODE
9600 bps 8 NO NONE
2. Change the desired parameters and press <Enter> to end.
Table D-10 describes the dial-out port’s parameters, function and range of values.
Table D-10. Dial-Out Port Communication Parameters
Parameter Function Values
SPEED
Selects the dial-out port data rate. The available selections are 300, 1200,
2400, 4800 or 9600 bps.
Default: 9600
DATA
Selects the number of data bits in
the dial-out port word format
The available selections are 7 or 8 data bits
Default: 8
PARITY
Controls the use of parity ODD – Odd parity.
EVEN – Even parity.
NO – Parity disabled (only available with 8
data bits)
Default: NO
CALL_OUT_MODE
Controls the use of the call-out
function
NONE – the call-out function is disabled.
ALL – FCD-E1 initiates a call after each new
alarm.
MAJOR – FCD-E1 initiates a call only when
a new major alarm condition is detected.
Default: NONE
DEF ML
Purpose
Select the main link parameters. Refer to Table D-2 for the parameter description,
allowable ranges and configuration guidelines.
Syntax
DEF ML
Use
1. To define the main link parameters, type:
DEF ML<Enter>