Unit installation

Installation and Operation Manual Appendix D Command Language
FCD-E1 Supervisory Terminal Commands D-23
ETHERNET MODE BRIDGING
HALF FILTER
In case the data channel has an Ethernet interface, this line is the last line of
the data form, and pressing <Enter> ends the command.
3. Change the desired parameters and then press <Enter> to display the next
line. A typical form is shown below.
MAP_MODE START_TS TS_TYPE
SEQ 1 NC
4. When done, press <Enter>.
If in step 3 the MAP MODE has been set to SEQ, FCD-E1 displays the time
and date followed by the FCD-E1 prompt.
If the MAP MODE has been set to USER, after you press <Enter> you will
see the first line of the timeslot map of the channel being currently
configured. A typical display is shown below:
TS : NO 01 NO 02 NO 03 NO 04 NO 05 NO 06 NO 07
NC NC NC NC NC NC NC
Use the spacebar to move between timeslots. For each timeslot, select
between DATA (timeslot allocated to the current channel) and NC (not
connected) by pressing <F> or <B>.
After completing the first line, press <Enter> to continue to the next
line. Repeat the procedure until all the timeslots are defined. The
maximum number of timeslots is 31.
5. When done, press <Enter> to end.
Table D-9 describes additional parameters of the data channel available only
through the supervisory terminal.
Table D-9. Additional Data Channel Parameters
Parameter Function Values
ETHERNET MODE
Selects the Ethernet LAN traffic
transfer mode.
For FCD-E1 without Ethernet
interface, this parameter is not
displayed
HALF – Half duplex operation.
FULL – Full duplex operation.
Default: HALF
BRIDGING
Selects the Ethernet traffic
processing mode.
For FCD-E1 without Ethernet
interface, this parameter is not
displayed
FILTER – The internal bridge of FCD-E1
is enabled, and filters the traffic
transferred to the remote end.
TRANS – The internal bridge of FCD-E1
is disabled, and the Ethernet traffic is
transparently transferred (LAN extender
function).
Default: TRANS