Unit installation

Appendix D Command Language Installation and Operation Manual
D-20 Supervisory Terminal Commands FCD-E1
DEF CALL
Purpose
Define the call-out parameters for the FCD-E1 dial-out port (connector CONTROL
DTE). The call-out function is enabled by means of the DEF DP port.
The specified call-out parameters are used by FCD-E1 to build the call command
that is sent to the dial-out modem. The modem connected to the CONTROL DTE
connector must be set up as follows (for convenience, the Hayes commands
required to select the specified parameters are listed in brackets):
Auto-answer mode (
AT S0=1)
Call set up in response to the
CONNECT string (AT X0)
No echo (
AT E0)
Verbose mode (no codes, e.g.,
CONNECT string instead of 0) (AT V1).
Syntax
DEF CALL
Use
1. To define the CONTROL DTE call-out parameters, type:
DEF CALL<Enter>
The first page of the call-out parameters data form appears.
NUM_OF_RETRIES WAIT_FOR_CONNECT DIAL_MODE
ALT_NUM_MODE
0 30 SEC TONE NO
2. Change the parameter values as follows:
Press the spacebar to bring the cursor to the beginning of the first field to
be changed.
Press F or B to scroll among the available selections and change the
selected field.
When the desired selection is displayed, press the spacebar to move to the
next field.
The call-out parameters displayed on the first page of the data form and their
range of values are explained in Table D-8.