Unit installation

Installation and Operation Manual Appendix D Command Language
FCD-E1 Supervisory Terminal Commands D-19
ALARM The alarm condition:
MAJOR ON Indication provided when a major alarm condition is
detected.
MAJOR OFF Indication provided when a major alarm condition
disappears.
MINOR ON Indication provided when a minor alarm condition is
detected.
MINOR OFF Indication provided when a minor alarm condition
disappears.
REPORT YES indicates that the corresponding alarm condition is
reported by means of traps sent to management stations.
DEF BERT
Purpose
Define the BERT test conditions. Refer to Table D-5 for the parameter description,
allowable ranges and configuration guidelines.
Syntax
DEF BERT CH {1 2}
Use
1. To define the BER test parameters for channel 1, type:
DEF BERT CH 1<Enter>
2. To define the BER test parameters for channel 2, type:
DEF BERT CH 2<Enter>
3. The BERT parameters data form is displayed:
PATTERN ERROR_INJECTION_RATE RX_INBAND
2E3-1 NO_ERR DISABLE
4. Move the cursor to the desired field using the spacebar, and then change using
the <F> or <B> keys. After making the desired selections, press <Enter> to
end.