Unit installation

Appendix D Command Language Installation and Operation Manual
D-18 Supervisory Terminal Commands FCD-E1
The functions of the fields are as follows:
ALARM NUMBER Displays the first alarm number (code and description) in the
selected group (see Chapter 5).
MASKED Enables the masking of the selected alarm:
YES The alarm is masked.
NO The alarm is not masked, and will be reported when
generated.
4. Select the desired state for the current alarm by pressing the <F> or <B>
key, and then press <Enter> to display the next alarm number. Repeat the
procedure until all the alarms in the selected group have been defined. After
the last alarm, you will see again the date and time, followed by the working
prompt.
DEF AR
Purpose
Control the use of traps for alarms reporting.
Syntax
DEF AR
Use
1. To define the alarm reporting and relay indications, type:
DEF AR<Enter>
FCD-E1 displays the alarm data form.
ALARM REPORT
MAJOR ON NO
2. To display an additional row, press <Enter>. A typical data form as seen after
all the lines have been displayed is shown below:
ALARM REPORT
MAJOR ON YES
MAJOR OFF YES
MINOR ON YES
MINOR OFF YES
3. To change the current selections, bring the cursor to the desired field, and
then press the <F> or <B> keys to display the desired mode (YES or NO).
When done, press <Enter> to end.
The data form lists the alarm conditions, and the action to be taken for each alarm
condition. The fields appearing on the data form are explained below.