Unit installation
Appendix D Command Language Installation and Operation Manual
D-12 Front Panel Parameters FCD-E1
Table D-6. Download Configuration Parameters
Designation Function Values Configuration Guidelines
MODE
Selects the inband
transmission mode for the
selected link
NONE – Inband SNMP and Telnet traffic is ignored
and FCD-E1 does not generate such traffic
TS0/F – Inband SNMP and Telnet traffic is received
and transmitted in timeslot 0
DEDIC – Inband SNMP and Telnet traffic is
received and transmitted in a dedicated, user-
selected timeslot
FR – For Main link only. Inband SNMP and Telnet
traffic is received and transmitted in a dedicated,
user-selected timeslot
Default: NONE
TS NUM
Selects the dedicated
timeslot used for the
selected link.
Any number in the range of 1 through 31,
consistent with the available timeslots
Default: 1
This parameter is displayed only when the DEDIC or
Frame Relay mode is selected
SPEED
Selects the data rate used to
transfer inband the
management traffic for the
selected link.
The management traffic data rate is given in kbps:
8, 16, 32, 64
Default: 8
This parameter is displayed only when the DEDIC or
Frame Relay mode is selected and is relevant to ML. The