Unit installation
Appendix D Command Language Installation and Operation Manual
D-6 Front Panel Parameters FCD-E1
Table D-3. Supervisory Configuration Parameters
Designation Function Values Configuration Guidelines
SPEED
Selects supervisory port data
rate.
300, 1200, 2400, 4800, 9600, 19200 – Supervisory
port data rates in bps
AUTO – Autobaud operation.
Default: AUTO
Select AUTO in order for FCD-E1 to automatically identify
the incoming traffic data rate.
To enable positive identification, the transmission must
start with three consecutive Carriage Returns.
Do not use Autobaud when the CONTROL DCE port is
configured for the SLIP protocol.
Note: The 19200 and AUTO selections are not available for the CONTROL DTE port
DATA
Selects the number of data
bits in the CONTROL DCE
port word format
7, 8 – Number of data bits
Default: 8
The supervisory port word format should be the same as
on the terminal.
PARITY
Controls the use of parity ODD – Odd parity
EVEN – Even parity
NO – Parity disabled
Default: NO
The supervisory port word format should be the same as
on the terminal.
INTERFACE
Selects interface of the
CONTROL DCE supervisory
port
DCE – The CONTROL DCE port appears as DCE
for external equipment
DTE – The CONTROL DCE port appears as DTE for
connection via modem to the external equipment
Default: DCE
Select DCE when FCD-E1 is connected directly to the
terminal.
Select DTE when FCD-E1 is connected to the terminal via
a modem.
AUX-DEV
Selects the management
mode supported by the
CONTROL DCE port.
TERMINAL – The CONTROL DCE port is
connected using an ASCII supervision terminal
SLIP-NMS – The DCE control port connects to an
SNMP management station and/or Telnet host using
the SLIP protocol
SLIP_AGN – The DCE control port connects to
another agent port using the SLIP protocol
Default: TERMINAL
Select SLIP-NMS when the supervisory port must be able
to use the SLIP protocol, for example SNMP or Telnet
management.
Select TERMINAL if only the supervision terminal must be
supported.
Note: At any time only one of the two ports of the FCD-E1 can be used for management access.