Unit installation

Installation and Operation Manual Appendix D Command Language
FCD-E1 Front Panel Parameters D-3
Table D-2. Link Configuration Parameters
Designation Function Values Configuration Guidelines
FRAME
Selects the multiframing
mode for the main link and
the sublink
G732N – 2 frames per multiframe. Timeslot 16 can
be used for user data.
G732S – 16 frames per multiframe.
UNFRM – Unframed G.703 signal, carrying the
data applied to channel 1
Default: G732N
Select the framing mode specified for use in your network
on the corresponding link. If some of the timeslots of a link
are configured as voice type slots, that link must use the
G732S mode, otherwise you will see CONFIG
ERROR 006.
For transmission of unframed data, select UNFRAME for
the main link. In this case, all the ports except channel 1
are disabled (the data rate of channel 1 is automatically set
to 2048 kbps).
SYNC
Used to change the frame
alignment algorithms, to
reduce the time required for
the link to return to normal
operation after loss of sync
CCITT – Complies with ITU-T Rec. G.732
FAST – After 1 second
62411 – Complies with AT&T TR-62411 (after 10 sec)
Default: CCITT
Select CCITT, unless your application has special
requirements.
FUNCTION
Displays the type of main
link interface
DSU – FCD-E1 does not include an LTU
LTU – FCD-E1 includes an LTU
IDLE CODE
Selects the code transmitted
to fill idle (unused) timeslots
in the main link frame
The following bit sequences are available
(presented as hexadecimal numbers): 7F, 98, FF.
You can also select any other sequence.
Default: 3F
Select one of the three commonly used values, 7F, 98 or
FF, or any value specified for use on the corresponding
link in your network. Select the same value at the other
end. FCD-E1 allows you to select any two-digit
hexadecimal value.
CRC-4
Enables the generation of
check bits (in accordance
with the CRC-4 polynomial
specified by ITU-T Rec.
G.704)
NO – CRC-4 option disabled
YES – CRC-4 option enabled
Default: NO
Select YES, except when FCD-E1 link is connected to
transmission equipment that does not support this option.
RAI
Selects whether remote
alarm indication is sent to
the sublink if a local or
remote alarm exists in the
main link.
DISABLE – RAI transfer disabled
ENABLE – RAI transfer enabled
Default: DISABLE