Unit installation
Appendix A Pinouts Installation and Operation Manual
A-10 Data Channel Connector FCD-E1
Table A-8. Wiring of X.21 Adapter Cable for DCE Mode (Cont.)
FCD-E1 Side Designation Function User’s Side
16 RDB Receive Data (wire B) 11
17 RCA Receive Clock (wire A) –
18 – Not connected –
19 RTSB RTS (wire B) 10
20 RCEA External Receive Clock (wire
A)
–
21 – Not connected –
22 DSRB DSR (wire B) –
23 RCEB External Receive Clock (wire B) –
24 SCEA External Send Clock (wire A) –
25 – Not connected –
V.36/RS-449 Data Channel
The following sections provide information on the cables required to connect
user’s equipment to the V.36/RS-449 channel in the various timing modes.
DCE Mode
This mode is used to connect to user’s equipment with V.36/RS-449 DTE
interface. The V.36/RS-449 cable coming from the user’s equipment is connected
to the FCD-E1 CHANNEL connector through an adapter cable. The adapter cable
(see Figure A-4) is terminated in a 25-pin male D-type connector at the
FCD-E1 side, and a 37-pin female connector at the user’s side. A suitable cable,
designated CBL-HS2/R/1, is available from RAD.
Cable wiring is given in Table A-9.
Figure A-4. V.36/RS-449 Adapter Cable for DCE Mode