6.6 Frequently Asked Questions
Question: Is it possible to split the bandwidth while working in unframed mode?
Answer: No, when you work in unframed mode, it is impossible to split the
bandwidth to more than one user. The E1 port transparently transfers the incoming
data stream on a bit-by-bit basis. This allows the transfer of Unframed 2048 kbps
data streams.
Question: Which management platform should I use in order to mange FCD-E1?
Answer: In order to mange FCD-E1 you should use RADview TDM over HPOV
and a Solaris platform.
Question: What is the sequence of commands necessary for configuring
FCD-E1/T1 in the DTE-2 clock mode?
Answer: In order to configure the FCD-E1/T1 in the DTE2 clock mode, you must
first define clock mode = DTE2. Use the command 'DEF CH 1' or 'DEF CH 2
(depending on which channel you want to configure as clock source).
Then you can configure with 'DEF SYS' Master Clock = CH1 or Master Clock =
CH2.
Question: Is there any MTU size (Maximum Transmission Unit) limitation if I have
a Cisco router and want to use inband management on one of the above products
by using a dedicated Frame Relay or PPP protocol?
Answer: Yes, the 'Maximum Transmission Unit' must be configured to 200.
Question: What are the software upgrade options for FCD-E1?
Answer: FCD-E1 with software version 0.30 and above can be upgraded to
version 1.00. The ordering option is: FCD-E1/EPROM/1.00.
Software version 0.2x can be upgraded up to version 0.23. The ordering option is:
FCD-E1/EPROM/0.23.
Software version 0.1x must be checked separately for compatibility with version
software 0.23.