Unit installation
Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics
FCD-E1 Handling Alarms 6-7
Table 6-2. FCD-E1 Configuration Error Messages (Cont.)
Error Code Terminal Message Description
ERROR 019 DEDICATED TIME SLOT IS NOT
MAPPED
Inband management is DEDIC TS or DEDIC FR and no
timeslot is selected for management.
ERROR 020 CALL OUT OCCUPIED BY
OTHER PORT
You can perform call-out only via the dial-out port or via
the supervisory port.
WARN 021 RX INBAND ENABLE, ALL CH/S
TRAFFIC STOP
You enabled the RX inband parameter on the sublink,
which caused traffic disruption on the data channel(s).
ERROR 51 ILLEGAL PORT LOOP
COMBINATION
You are trying to activate the remote loopback while the
local loopback is already activated on the same port, or
vice versa. First deactivate the currently active loopback.
ERROR 52 LOOP IS NOT ACTIVE You are trying to deactivate a loopback or test that is not
active. Check and change as required.
ERROR 53 CURRENT LOOP ALREADY
BEING PERFORMED
You are trying to activate a loopback that is already active.
Check and change as required.
ERROR 54 ILLEGAL PARAMETER FOR
CURRENT CONFIGURATION
You are using a parameter that is not supported by this
FCD-E1 version.
ERROR 55 ILLEGAL COMMAND FOR
CURRENT PORT MODE
You are trying to select a parameter value that is not
supported under the current link framing mode. Check
and change as required.
ERROR 59* REPETITIVE MODE CAN'T BE
PERFORMED ON TELNET
You are trying to use a command with /R option while
using Telnet for management. This is not allowed.
ERROR 60 CANT PERFORM LOOP -
CHANNEL NOT CONNECTED
You are trying to activate a loopback on a channel that is
not connected.
ERROR 61* ILLEGAL FIELD VALUE The value enterd in the specified field is not allowed.
Check and correct as required.
ERROR 062 BERT/INBAND SL LOOP STOP
ALL DATA TRAFFIC FROM CH2
You activated BER testing or inband loop on the sublink,
which caused traffic disruption on channel 2.
6.3 Handling Alarms
FCD-E1 maintains an alarm buffer that can store up to 100 alarm messages.
Alarm Display
FCD-E1 displays alarm messages both on the front-panel LCD and on the
supervision terminal. Alarms can be of two types, designated as ON/OFF and ON:
• An ON/OFF-type alarm is displayed only when the alarm condition is present,
and is automatically removed when the condition is cleared (if the alarm is
being displayed, it will disappear only when the display is refreshed by
scrolling).
• An ON-type alarm persists even after the event that caused the alarm
condition is cleared.