Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics
FCD-E1 Detecting Errors 6-5
• If the self-test is successfully completed, FCD-E1 starts normal operation, and
its front-panel indicators display the link status, as explained in Chapter 3.
Front-Panel LEDs
The status of FCD-E1 is indicated by the front-panel LEDs. For description of LED
indicators and their functions refer to Chapter 3.
Configuration Error Messages
If FCD-E1 detects a configuration mismatch, it displays an appropriate
configuration error message. These messages appear on either the LCD or the
supervision terminal. Some of the messages are not available on the LCD.
On the control terminal, configuration error messages have the format ERROR,
followed by a two-digit code and a short description of the error message after the
error code. The LCD displays CONFIG ERROR followed by the error two-digit
code, without description. Table 6-2 lists the configuration error messages in order
of their codes and explains each of them. Messages not available on the LCD are
marked with an asterisk (*).
Table 6-2. FCD-E1 Configuration Error Messages
Error Code Terminal Message Description
ERROR 00 MASTER AND FALLBACK
CLOCK ARE THE SAME
You are trying to select the same source as both master
and fallback clock source. Check and change as required.
ERROR 01 INVALID MASTER CLOCK
SOURCE
The channel you are trying to select as the master clock
source is either not connected, or its clock mode is not
DTE2. Check and change as required.
ERROR 02 INVALID FALLBACK CLOCK
SOURCE
The channel you are trying to select as the master clock
source is either not connected, or its clock mode is not
DTE2. Check and change as required.
ERROR 03* ILLEGAL DCD DELAY AND
INTERFACE
You are trying to select a non-zero DCD DELAY after the
FCD-E1 supervisory port interface has been set as DCE.
ERROR 04* CONFLICT IN INTERFACE AND
DSR PARAMETERS
You selected DSR=ON after the supervisory port
interface has been set to DTE. The DSR=ON selection is
valid only for DCE interface.
ERROR 05 TIME SLOT 16 OF E1-G732S
FRAME IS MAPPED
You are trying to select the G732S framing mode while
time slot 16 is assigned to a data channel, the sublink, or
dedicated to inband management. Free time slot 16
before selecting the G732S framing.
ERROR 06 CONFLICT BETWEEN FRAME
AND TIME-SLOT TYPES
You are trying to define a sub time slot as a voice time
slot, but the main link framing mode is G732N (the voice
type can be selected only when the framing mode is