Unit installation

Installation and Operation Manual Chapter 5 Configuring Typical Applications
FCD-E1 Configuration Example 5-5
Use the out-of-service code 3F
Transfer 10 subscriber timeslots and the signaling timeslot (timeslot 16)
through the main link.
After configuration, the following display appears:
FRAME CRC-4 SYNC RX_GAIN IDLE_TS_CODE
RAI
G732N NO CCITT SHORT 7F
ENABLE
CGA OOS_SIG OOS_CODE
NONE N/A 3F
MAP_MODE START_TS TS_TYPE NUM_OF_TS
USER N/A N/A N/A
TS : 1 2 3 4 5 6 7 8
TYPE : DATA DATA NO NO NO NO VOICE VOICE
TS : 9 10 11 12 13 14 15 16
TYPE : VOICE VOICE VOICE VOICE VOIC VOICE VOICE DATA
TS : 17 18 19 20 21 22 23 24
TYPE : VOICE NO NO NO NO NO NO NO
TS : 25 26 27 28 29 30 31
TYPE : NO NO NO NO NO DEDIC NO
Configure Data Channel Parameters
Type DEF CH 1 to define the data channel characteristics and connect it to the
main link timeslots 1 and 2.
After configuration, the following display appears:
MULTIPLIER SPEED FIFO_SIZE CLOCK MODE CTS
CLOCK_POLARITY
64 128 AUTO DCE ON NORMAL
MAP_MODE START_TS TS_TYPE
SEQ 1 DATA
TS : 1 2 3 4 5 6 7 8
TYPE : DATA DATA NO NO NO NO NO NO
TS : 9 10 11 12 13 14 15 16
TYPE : NO NO NO NO NO NO NO NO
TS : 17 18 19 20 21 22 23 24
TYPE : NO NO NO NO NO NO NO NO
TS : 25 26 27 28 29 30 31
TYPE : NO NO NO NO NO DEDIC NO
Check Main Link Timeslot Assignment
Type DSP TS to check main link timeslot assignment.
The resulting display appears: