Unit installation
Chapter 5 Configuring Typical Applications Installation and Operation Manual
5-4 Configuration Example FCD-E1
OLD AGENT PARAMETERS
IP_ADDRESS IS : = 0.0.0.0
READ COMMUNITY IS : = public
WRITE COMMUNITY IS : = private
TRAP COMMUNITY IS : = public
TELNET_APATHY_TIME
10 MIN
IP_ADDRESS IS : = 192.114.029.209
READ COMMUNITY IS : = public
WRITE COMMUNITY IS : = RAD
TRAP COMMUNITY IS : = public
6. Type DEF DNLOAD ML to configure the FCD-E1 inband management
parameters for the main link:
Management mode: Frame Relay
Network management traffic carried in timeslot 30.
A typical display, as seen after the required parameters have been selected, is
shown below:
DNLOAD MODE
FRAME_RL
TS_NUM SPEED
30 64
Configure Main Link Parameters
Type DEF ML to define the required main link parameters:
E1 link interface operating mode: LONG
Framing mode: G.732N
Enable the CRC-4 function (YES)
Set the idle timeslot code to 7F
Enable transparent reporting of sub link alarms through the main link (RAI
= ENABLE).
After configuration, the following display appears:
FRAME CRC-4 SYNC RX_GAIN IDLE_TS_CODE RAI
G732N YES CCITT LONG 3F ENABLE
Configure Sub Link Parameters
Type DEF SL to define the required sub link parameters:
E1 link interface operating mode: SHORT
Framing mode: G.732S
Enable the CRC-4 function (YES)
Set the idle timeslot code to 7F
Enable transparent reporting of sub link alarms through the main link
(RAI = ENABLE)