FCD-E1 Using the Menu-Driven Command Mode 4-19
Table 4-5. Mnemonic Mode Menu Structure (Cont.)
MM Main Menu
(Cont’d) MC Clear Commands Menu
CA Clear alarms stored in the FCD-E1 alarm buffer
CM Main link clear commands submenu
CLAM Deactivate local analog loopback on the main link
CLDM Deactivate local digital loopback on the main link
CRAM Deactivate remote analog loopback on the main link
CRDM Deactivate remote digital loopback on the main link
CS Sublink clear commands submenu
CLAS Deactivate local analog loopback on the sublink
CLDS Deactivate local digital loopback on the sublink
CRAS Deactivate remote analog loopback on the sublink
CRDS Deactivate remote digital loopback on the sublink
CBS Deactivate BER testing on the sublink
CIS Deactivate inband loop on the sublink
C1 Channel 1 clear loopback commands
CL1 Deactivate local loopback on channel 1
CR1 Deactivate remote loopback on channel 1
CB1 Stop the BER test on channel 1
CI1 Deactivate remote inband-activated loopback on channel 1
C2 Channel 2 clear loopback commands
CL2 Deactivate local loopback on channel 2
CR2 Deactivate remote loopback on channel 2
CI2 Deactivate remote inband-activated loopback on channel 2
MD Define Menu
DM Configure main link parameters
DS Configure sublink parameters
D1 Configure the parameters of channel 1
D2 Configure the parameters of channel 2
DY Configure the system parameters
DP Configure supervisory port parameters
DX Define the node number of the FCD-E1
DN Define the logical name of the FCD-E1
DW Define the new password, and/or display the current password
DF Reserved
DA Define the alarms to be masked (ignored)
DC Define CALL OUT parameters
DO Define DIAL PORT parameters