Specifications
Chapter 5 Configuring FCD-E1LC for a Typical Application Installation and Operation Manual
5-6 Configuration Example FCD-E1LC Ver. 1.0
MULTIPLIER SPEED FIFO_SIZE CLOCK MODE CTS CLOCK_POLARITY
64 128 AUTO DCE ON NORMAL
MAP_MODE START_TS TS_TYPE
SEQ 1 DATA
TS : 1 2 3 4 5 6 7 8
TYPE : DATA DATA NO NO NO NO NO NO
TS : 9 10 11 12 13 14 15 16
TYPE : NO NO NO NO NO NO NO NO
TS : 17 18 19 20 21 22 23 24
TYPE : NO NO NO NO NO NO NO NO
TS : 25 26 27 28 29 30 31
TYPE : NO NO NO NO NO DEDIC NO
Check Main Link Timeslot Assignment
Type DSP TS to check main link timeslot assignment.
The resulting display is shown:
TS : 01 02 03 04 05 06 07 08 09 10
TYPE : DATA DATA NC NC NC NC VOICE VOICE VOICE VOICE
DEST : CH1 CH1 NA NA NA NA SUB SUB SUB SUB
TS : 11 12 13 14 15 16 17 18 19 20
TYPE : VOICE VOICE VOICE VOICE VOICE DATA VOICE NC NC NC
DEST : SUB SUB SUB SUB SUB SUB SUB NA NA NA
TS : 21 22 23 24 25 26 27 28 29 30 31
TYPE : NC NC NC NC NC NC NC NC NC NC NC
DEST : NA NA NA NA NA NA NA NA NA DEDIC NA
Configure System Timing
Type DEF SYS to configure the FCD-E1LC nodal timing:
Lock FCD-E1LC timing to the recovered main link clock
Use the internal oscillator as fallback source.
After configuration, you should see the following display:
CLK_MASTER CLK_FBACK DATE_FORMAT
ML NONE DD-MM-YYYY
Configuring the Remote FCD-E1LC
Repeat the procedure for the other FCD-E1LC.