Specifications
Installation and Operation Manual Chapter 5 Configuring FCD-E1LC for a Typical Application
FCD-E1LC Ver. 1.0 Configuration Example 5-3
DXC
RADview
Station
Router
E1 Network
FCD-E1LC
128 kbps
V.35
PBX
FCD-E1LC
128 kbps
V.35
PBX
Figure 5-1. FCD-E1LC Application for Configuration Examples Interconnected by
an E1 Network
Configuring the Local FCD-E1LC
Configure General System Parameters
1. Type INIT DB to reset the FCD-E1LC database to the default parameters.
2. Type DEF TERM VT-100 to configure the control port to operate with the
terminal control codes of the VT-100 terminal.
3. Type DEF SP to configure the control port.
A typical display, as seen after the required parameters have been selected,
is shown below:
SPEED STOP_BITS PARITY INTERFACE CTS DCD_DEL
DSR
AUTO 8 NO DCE =RTS 0 MS
ON
POP_ALM PWD LOG_OFF CALL_OUT_TRIGER ACTIVATE_CALL_OUT
AUXILIARY_DEVICE
NO NO NO NONE ANY CASE
TERMINAL
4. Type DEF MANAGERS LIST to configure the FCD-E1LC to accept one
RADview management station:
The RADview station IP address is 192.114.029.201
The total number of managed units is 16, therefore the subnet mask is
255.255.255.240.
A typical data form, as seen after the rows used to define the first
management station have been filled in, is shown below: