Specifications
Chapter 5 Configuring FCD-E1LC for a Typical Application Installation and Operation Manual
5-2 Configuration Example FCD-E1LC Ver. 1.0
Table 5-1. Outline of Configuration Procedures
Step Activity Reference
Perform the preliminary configuration
Chapter 3
Define system configuration DEF SYS
Configure the FCD-E1LC main link DEF ML
Configure each FCD-E1LC port and its connections to
the main link
DEF SL
DEF CH1
DEF CH2
Define the general system parameters DEF AGENT
DEF MANAGER LIST
DEF ROUTE
DEF NAME
DEF PROMPT
DEF PWD
Define dial-up parameters (when applicable) DEF CALL
Define alarm handling parameters DEF ALM MASK
DEF AP
DEF AR
5.2 Configuration Example
This section illustrates the procedure details for configuring two FCD-E1LC units
using a supervision terminal, for a typical application (see
Figure 5-1
).
In this application, two FCD-E1LC units, each having one data channel and a sub
link, are interconnected via the E1 network and managed by a RADview network
management station attached to a DXC unit. The data channel rate is 128 kbps,
the number of voice channels to be connected between the two PBXs is 10, and
the management station is connected to both FCD-E1LC units via the main links.