Specifications
Installation and Operation Manual Chapter 4 Configuration
FCD-E1LC Ver. 1.0 FCD-E1LC Command Language 4-5
Configure the FCD-E1LC Control Port for Telnet and SNMP
Access
To use the FCD-E1LC control port for Telnet and SNMP access, use the DEF SP
commands, as applicable, and select the following parameters:
• Select the appropriate data rate in the SPEED field. Do not select AUTO.
• Select NMS SLIP or NMS PPP in the AUXILIARY DEVICE field.
When using SLIP, if the FCD-E1LC control port is connected to a serial port of
another RAD equipment unit, for example, a Megaplex-2100/2104, make sure to
select
SLIP AGENT
in the
AUXILIARY DEVICE
field.
At this stage, you can start using Telnet hosts or SNMP management stations to
perform FCD-E1LC configuration activities.
Ending the Control Session
Type EXIT to end a supervision terminal session.
Type BYE to end a Telnet session.
4.2 FCD-E1LC Command Language
This section presents the FCD-E1LC command language, its syntax and command
options, and an index of the supported commands.
Command Syntax
This section presents the supervision language syntax.
Enter commands at the FCD> prompt. This prompt appears at the beginning of
each new line. The cursor appears to the right of the prompt.
If a node number is required, enter the node number before the command using
the following syntax:
NODE<SP>‘node number’<SP>‘command’<Enter>.
FCD-E1LC echoes commands as you enter them, character by character.
Use <Space> as a separator between command fields and/or parameters.
To correct typing errors, press <Backspace> until the error is cleared, then enter
the correct characters.
To execute a command, press <Enter>. After when the command is executed,
FCD-E1LC displays the current date and time, and then displays a new command
prompt.
After the last page of the data form, press <Enter> to initiate command
evaluation.