Specifications

Installation and Operation Manual Chapter 4 Configuration
FCD-E1LC Ver. 1.0 Configuring for Management 4-3
Preliminary Configuration
Perform the procedure explained below. If you need detailed instructions and
explanations regarding each command, refer to
Appendix D
.
For detailed instructions regarding the use of the FCD-E1LC command line
interface, refer to
Section 4.2
.
Load the Factory-Default Parameters
To load the default parameters, enter the INIT DB command.
Select the Supervisory Terminal Control Sequences
Select the terminal control sequences for the terminal type (or emulation) in use
by entering the command DEF TERM 'terminal_type'. 'terminal_type'
stands for one of the following types: VT-52, VT-100, TV-920, FREEDOM100,
FREEDOM220.
If your terminal requires control sequences differing from those used by the
terminals listed above, type the command F and enter your terminal control
sequences.
Configure the CONTROL DCE Port
Configure the CONTROL DCE port of the FCD-E1LC system by entering the
command DEF SP. You will see the supervisory port configuration data form.
A typical form with the default values is shown below:
SPEED STOP_BITS PARITY INTERFACE CTS DCD_DEL DSR
AUTO 1 NONE DCE =RTS 0_MS ON
POP_ALM PWD LOG_OFF CALL_OUT_TRIGGER ACTIVATE_CALL_OUT
AUXILIARY_DEVICE
NO NO NO NONE ANY CASE
TERMINAL
Set the Time and Date for the Internal Clock
Set the time of the internal clock of the FCD-E1LC system by entering the
command TIME, and then set the date by entering the command DATE.
The time and date must be set whenever the FCD-E1LC is powered up (either
after a power failure or after being turned off).
At this stage, you can start using the supervision terminal to perform FCD-E1LC
configuration activities.
Activate Password Protection
To prevent unauthorized modification of the FCD-E1LC system parameters, you can
use a password. The use of a password is controlled by the DEF SP command.
After enabling password protection, define the desired password by entering the
command DEF PWD.
Note