Specifications

Chapter 2 Installation and Setup Installation and Operation Manual
2-14 Setting the Internal Jumpers and Switches FCD-E1LC Ver. 1.0
Table 2-4. Switch SW2 Functions (Cont.)
Section Function
PSW
FCD-E1LC is delivered with a default password, RAD. However, to prevent unauthorized personnel
from using the FCD-E1LC supervision program, you can use a password of your own.
ON FCD-E1LC uses the default password.
OFF FCD-E1LC uses the user-defined password.
Default: OFF
The FCD-E1LC polling address (node number) is also affected by the PSW section: with this
section set at ON, the node number is set to 0. Upon first-time operation, it is recommended to
use the ON position to start the configuration. You can select this position again to restart with
the default password and node address 0 in case the current user password was lost.
Note You can use the DEF SP command to cancel password protection. In this case, no
password is used, irrespective of the position of this switch section.
DEF PAR
This section selects the source of the supervisory port parameters.
ON FCD-E1LC loads the factory-default supervisory port parameters (automatic detection of
any standard data rate in the range of 1200 to 115,200 bps, one start bit, 8 data bits, no
parity, one stop bit, terminal mode).
OFF Supervisory port operates according to user-defined parameters.
Default: OFF
Note User-selected parameter values are not erased by setting one or more sections of switch
SW2 to ON: this action merely causes FCD-E1LC to use the default values. However, if
FCD-E1LC is powered off and then on again, the default values replace the user values.
Closing the Unit
³ To close FCD-E1LC enclosure:
1. Refer to
Figure 2-7
, and place cover as shown.
Figure 2-7. Closing the FCD-E1LC Cover