Specifications
Installation and Operation Manual Chapter 2 Installation and Setup
FCD-E1LC Ver. 1.0 Setting the Internal Jumpers and Switches 2-13
ON
SW2
OFF
Not Used (Always OFF)
Switch
SW2
Figure 2-6. FCD-E1LC, Location of Switch SW2
2. The functions of SW2 switch sections are explained in
Table 2-4
. Check and if
necessary change the positions of the various sections in accordance with
your requirements.
Table 2-4. Switch SW2 Functions
Section Function
INIT_DB This section selects the source of the configuration database parameters.
FCD-E1LC is delivered with its configuration database loaded with the factory default parameters.
You can select this position again to restart with the default parameters in case the current
values are not known.
ON FCD-E1LC loads the factory-default parameters upon power-up.
OFF FCD-E1LC loads the user-selected parameters from its non-volatile memory on power-up.
Default: OFF
Note: User-selected parameter values are not erased by setting the DB INIT section to ON. Only
after FCD-E1LC is turned off and then powered again, do the default values replace the
user values.