Specifications

Chapter 2 Installation and Setup Installation and Operation Manual
2-10 Setting the Internal Jumpers and Switches FCD-E1LC Ver. 1.0
2.6 Setting the Internal Jumpers and Switches
Before starting, review the safety and ESD precautions given in
Section 2.1
.
The FCD-E1LC preliminary configuration is performed by means of a supervisory
terminal. To protect against unauthorized use, you must enter a password before
you can start using the supervisory terminal.
In case you do not know the password and/or the communication parameters of
the serial supervisory port, it is necessary to restore the default values before
you can start configuration activities.
The FCD-E1LC includes an internal switch (marked SW2 on the FCD-E1LC main
printed circuit board) that controls the loading of the default parameters.
This section presents instructions for reaching the internal switch.
If you can use the supervisory terminal to enter the INIT DB command, you may
skip this section.
It is also recommended to check the settings of the internal switch in case the
configuration data prepared by you is lost after resetting (or turning off and on
again) the FCD-E1LC: usually, this indicates that the FCD-E1LC switch is set to
reload the factory-default parameters upon power-up.
For some FCD-E1LC hardware versions, it is not necessary to open the enclosure
to reach the switch: in these versions, the switch is located under the main
printed circuit board and can be accessed by opening a small cover on the bottom
of the FCD-E1LC case.
³ To reload the default parameters by means of the internal switch:
1. Open the FCD-E1LC enclosure as explained below.
2. Set the INIT_DB section of switch SW2 to ON.
3. Arrange the FCD-E1LC for safe operation with the cover open.
4. Connect power to the FCD-E1LC.
5. Wait about 2 minutes, and then disconnect the power from the FCD-E1LC.
6. Set the INIT_DB section of switch SW2 to OFF.
7. Close the FCD-E1LC cover as explained on page
2-14
.
Opening the Unit
³ To open the FCD-E1LC enclosure:
1. Refer to
Figure 2-3
and open the screws that fasten the FCD-E1LC cover.
Keep screws in a safe place, for reuse.
Caution
Note