Specifications

Installation and Operation Manual Chapter 2 Installation and Setup
FCD-E1LC Ver. 1.0 FCD-E1LC Enclosures 2-9
Table 2-3. FCD-E1LC Rear Panel Components
Item Function
POWER Connector Power connector, for connection of the supply voltage (either AC or DC)
CH.1 Connector 25-pin D-type female connector, for connection to the channel 1 data port
(interface type depends on ordering option)
CH.2 Connector 25-pin D-type female connector, for connection to the optional channel 2 data
port (interface type depends on ordering option)
CH.2 10/100BASE-T
Connector
RJ-45 connector for connection to the optional Ethernet LAN port, which has a
10/100Base-T interface
CH.2 10/100BASE-T
LINK Indicator
Green indicator located in the CH.2 10/100BASE-T connector:
Lights steadily when the LAN port detects the link integrity signal (normal
condition when there is no data activity)
Off when the port does not detect the link integrity signal
CH.2 10/100BASE-T
ACT Indicator
Yellow indicator located in the CH.2 10/100BASE-T connector, flashes or lights
when the LAN port transmits or receives data (normal operating condition)
CH.2 10/100BASE-T
100M Indicator
Green indicator for the optional LAN port:
Lights steadily when the LAN port operates at a data rate of 100 Mbps
Off when the LAN port operates at a data rate of 10 Mbps
E1/T1 MAIN Connector RJ-45 connector for connection to the main link interface
E1/T1 SUB Connector RJ-45 connector for connection to the optional sublink interface
CONTROL DCE Connector 9-pin female D-type connector for connection to the FCD-E1LC supervisory
terminal port
E1/T1 LOOPBACK Selector 4-section switch, controls the main and sublink analog test loopbacks. For a
description of the loopbacks, refer to
Chapter 4
.
Section
SUB L
SUB R
MAIN L
MAIN R
Function
Controls the sublink analog local loopback.
Controls the sublink analog remote loopback.
Controls the main link analog local loopback.
Controls the main link analog remote loopback.
To change the state of a loopback:
To activate a loopback using this switch, set the corresponding switch
section to ON. The TST indicator on the front panel will light.
To deactivate a loopback, return the switch to OFF. If no other test is active
on the FCD-E1LC, the TST indicator on the front panel will turn-off.
Note that the same activities can be performed by management (for example,
using the supervisory terminal). The actual state of a loopback is therefore
determined by the last command (either from the management or the switch).