Specifications

Installation and Operation Manual Chapter 2 Installation and Setup
FCD-E1LC Ver. 1.0 Package Contents 2-5
The port supports automatic MDI/MDIX detection and cross-over, and therefore
can be connected by any type of cable (standard or crossed) to any type of
10/100Base-T Ethernet port (station or hub).
CONTROL DCE Port Connections
The CONTROL DCE supervisory port has a 9-pin D-type female connector with
RS-232 interface.
The interface (DCE or DTE) is software-selectable. The default selection, DCE,
enables direct connection to terminals and management stations; when the
interface is configured as DTE, it is necessary to use a crossed adapter cable.
Front and Rear Panel Clearance
Allow at least 90 cm (36 inches) of frontal clearance for operator access.
Allow at least 10 cm (4 inches) clearance at the rear of the unit for interface
cable connections. However, during installation, replacement, and cable
connections, at least 90 cm (36 inches) is needed.
Ambient Requirements
The ambient operating temperature of the FCD-E1LC is 0 to 50°C (32 to 122°F),
at a relative humidity of up to 90%, non-condensing.
The FCD-E1LC units are cooled by free air convection; therefore, in rack
installations it is necessary to leave sufficient space (at least 1U) above and
below each unit, to enable free airflow.
2.3 Package Contents
The FCD-E1LC package includes the following items:
FCD-E1LC unit
Multiservice Access Devices and Intelligent CLEs CD-ROM
AC power cord or AC/DC adapter plug (if ordered)
Rack-mount (RM) kit (if ordered)
Interface adapter cable(s), in accordance with order.