Specifications

Chapter 1 Introduction Installation and Operation Manual
1-28 Technical Specifications FCD-E1LC Ver. 1.0
Diagnostics
Test Loops
E1 main link local analog loopback
E1 main link local digital loopback
E1 main link remote analog loopback
E1 main link remote digital loopback
E1 sublink local analog loopback
E1 sublink local digital loopback
E1 sublink remote analog loopback
E1 sublink remote digital loopback
Data channel local loopback
Data channel remote loopback
BER test on selected timeslots of the main
link
Inband FT1/FE1 code-activated loopback on
the main link
Note
: No loopback can be activated for the
Ethernet interface.
Statistics Collection
As per ITU-T Rec. G.706, G.826 with local
support as per RFC 4016
Alarms
Alarm Buffer
Alarm buffer size: 100 alarms. Last 100 alarms
are stored and available for retrieval.
Each alarm is time stamped (internal clock
without battery backup – must be set to
correct time after turn-off or power failure)
Indicators
Front Panel Indicators
PWR – FCD-E1LC is powered (green)
SYNC LOSS LOC MAIN – Loss of local
synchronization alarm on the main link (red)
SYNC LOSS REM MAIN – Loss of remote
synchronization alarm on the main link (red)
SYNC LOSS LOC SUB – Loss of local
synchronization alarm on the sublink (red)
SYNC LOSS REM SUB – Loss of remote
synchronization alarm on the sublink (red)
TST – test active (yellow)
ALM – alarm indication (red)
Rear Panel Ethernet
Interface Indicators
LINK (green) – LAN link integrity
ACT (yellow) – LAN data activity
100M – operation at 100 Mbps