Specifications

Appendix D Supervision Terminal Commands Installation and Operation Manual
D-54 Commands FCD-E1LC Ver. 1.0
LOOP REM DIG ML<Enter> or LP REM DIG ML<Enter>
LOOP BERT ML<Enter> or LP BERT ML<Enter>
LOOP INBAND ML<Enter> or LP INBAND ML<Enter>
2. To activate all the sublink loopbacks and tests, type:
LOOP SL<Enter> or LP SL<Enter>
To activate a specific sublink loopback or test, type:
LOOP LOC ANA SL<Enter> or LP LOC ANA SL<Enter>
LOOP REM ANA SL<Enter> or LP REM ANA SL<Enter>
LOOP LOC DIG SL<Enter> or LP LOC DIG SL<Enter>
LOOP REM DIG SL<Enter> or LP REM DIG SL<Enter>
3. To activate a data channel loopback, type:
LOOP LOC CH 1<Enter> or LP LOC CH 1<Enter>
LOOP LOC CH 2<Enter> or LP LOC CH 2<Enter>
LOOP REM CH 1<Enter> or LP REM CH 1<Enter>
LOOP REM CH 2<Enter> or LP REM CH 2<Enter>
Inband loopback and BER testing are available on channel 1 only.
The activation of an inband loopback is made by repeatedly transmitting the
activation sequence, therefore the loopback can be considered as activated
only after approximately 2 seconds.
If the requested loopback is already active, you will receive ERROR 053: CURRENT
LOOP ALREADY BEING PERFORMED. If the requested loopback is not supported by
the FCD-E1LC version, you will receive ERROR 055: LOOP NOT SUPPORTED ON
CURRENT FCD TYPE.
If you are trying to activate a loopback on a data channel of an FCD-E1LC with
Ethernet interface, you will see ERROR 056: ILLEGAL COMMAND FOR CURRENT
PORT MODE. Nevertheless, the BERT test (LOOP BERT) is allowed.
RESET
Purpose
Reset the FCD-E1LC system.
Syntax & Use
To reset the FCD-E1LC, type:
RESET<Enter>
You are requested to confirm the operation.
TIME
Purpose
Set the time for the FCD-E1LC internal clock.
Notes