Purpose
Activate the specified user-initiated test or loopback. If you want to activate an
additional loopback or test while another is already activated, first refer to
Chapter 4
for lists of allowed combinations.
If you try to activate a loopback or test not allowed at this stage, you will see
ERROR 051 - ILLEGAL PORT LOOP COMBINATION).
The FCD-E1LC rear-panel E1/T1 LOOPBACK switch can also be used to activate the
following loopbacks:
•
Main link local analog loopback
•
Main link remote analog loopback
•
Sublink local analog loopback
•
Sublink remote analog loopback.
The functions of this switch are described in Chapter 2. To activate a loopback,
the corresponding switch section must be set to ON.
Syntax
LOOP {‘loopback’}
Use
1. To activate all the main link loopbacks and tests, type:
LOOP ML<Enter> or LP ML<Enter>
To activate a specific main link loopback or test, type:
LOOP LOC ANA ML<Enter> or LP LOC ANA ML<Enter>
LOOP REM ANA ML<Enter> or LP REM ANA ML<Enter>
LOOP LOC DIG ML<Enter> or LP LOC DIG ML<Enter>
Note