Specifications

Appendix D Supervision Terminal Commands Installation and Operation Manual
D-48 Commands FCD-E1LC Ver. 1.0
DOWNLOAD MODE Displays the inband management mode selected for the
main link: TS0/F or FRAME RL
OOS CNTR Displays the number of local loss of frame alignment events
detected since the last time the counters were cleared.
BPV LAST MINUTE Displays the number of BPV events detected in the last
minute.
BPV WORST MINUTE Displays the number of BPV events detected during the
worst minute since the last time the counters were cleared.
DSP ST SL
Display sublink status information.
Syntax
DSP ST SL [/C]
Use
The sublink configuration parameters are similar to those of the main link, except
that there are no BERT, RX_INBAND and TX_INBAND fields. Refer to the DSP ST ML
command for detailed information.
DSP ST SYS
Purpose
Display system status information.
Syntax
DSP ST SYS
Use
To view the system status, type:
DSP ST SYS<Enter>
A typical system status display is shown below.
NODE = ‘node number’
NAME = ‘FCD-E1LC name’
NODAL CLOCK = INT
SOFTWARE VER = 01.00
HARDWARE VER = 00.02
FCD TYPE = E1/2
POWER SUPPLY = AC
The fields included in the system status information displays are listed below:
NODE The node number (0 through 255) assigned to the
FCD-E1LC.
NAME The system name assigned to the FCD-E1LC.