Specifications

Installation and Operation Manual Appendix D Supervision Terminal Commands
FCD-E1LC Ver. 1.0 Commands D-33
SPEED STOP_BITS PARITY INTERFACE CTS DCD_DEL
DSR
AUTO 8 NO DCE =RTS 0 MS
ON
2. Change the parameter values by bringing the cursor to the beginning of the
field to be changed using the spacebar, and then press <F> or <B> to scroll
among the available selections. When the desired selection is displayed, press
the spacebar to move to the next field.
3. When done, press <Enter> to display the second row of the supervisory port
parameters data form. A typical display is shown below.
POP_ALM PWD LOG_OFF CALL_OUT_TRIGER ACTIVATE_CALL_OUT
AUXILIARY_DEVICE
NO NO NO NONE ANY CASE
TERMINAL
4. After the desired parameter values are selected, press <Enter> to end, and
then press <Enter> to reconnect to the FCD-E1LC.
Table D-9. Supervisory Port Configuration Parameters
Parameter Function Values Configuration Guidelines
SPEED
Selects supervisory
port data rate.
1200, 2400, 4800, 9600,
19200, 38400, 57600,
115200 – Supervisory port data
rates in bps
AUTO – Autobaud operation.
Default: 19200 or AUTO
Select AUTO in order for the
FCD-E1LC to automatically
identify the incoming traffic
data rate. In this case, to
enable positive identification of
the data rate, each connection
to the supervisory port must
start with three consecutive
<Enter>.
Do not use AUTO when the
CONTROL DCE port is
configured to use the SLIP or
PPP protocol: in this case, you
may lose the communication
with the FCD-E1LC and you
may have to reload the
factory-default parameters.
STOP_BITS
Selects the number
of stop bits in the
CONTROL DCE port
word format
1, 2 – Number of data bits
Default: 1
The supervisory port word
format should be the same as
on the terminal.
PARITY
Controls the use of
parity
ODD – Odd parity.
EVEN – Even parity.
NONE – Parity disabled.
Default: NONE
The supervisory port word
format should be the same as
on the terminal.