Specifications

Appendix D Supervision Terminal Commands Installation and Operation Manual
D-30 Commands FCD-E1LC Ver. 1.0
6. If in Step 4 the MAP_MODE has been set to USER, the START_TS, TS_TYPE
and NUM_OF_TS fields are automatically set to N/A. In this case, press
<Enter> to continue.
You will see the first row of the data channel timeslot assignment map. A
typical display is shown below:
TS : 1 2 3 4 5 6 7 8
TYPE : NO NO NO NO NO NO NO NO
Use the spacebar to move between timeslots. For each timeslot, select
between NC, DATA and VOICE by pressing <F> or <B>.
After completing the first row, press <Enter> to continue to the next row.
Repeat the procedure until all the timeslots (up to 31) are configured.
7. Pressing <Enter> after the last timeslot ends the command.
Table D-8. Sublink Configuration Parameters
Designation Function Values Configuration Guidelines
FRAME
Selects the framing mode
for the sublink
See
Table D-7
Select the framing mode specified
for the equipment connected to
the sublink.
CRC-4
See
Table D-7
SYNC
See
Table D-7
RX GAIN
See
Table D-7
IDLE_TS_
CODE
See
Table D-7
RAI
Controls the transfer of the
RAI (remote alarm
indication) from the sublink
to the main link
ENABLE – The reception of RAI
by the sublink interface causes
the FCD-E1LC main link interface
to send RAI to the equipment
connected to the main link.
DISABLE – The RAI indication
sent by the main link is not
affected by RAI reception via the
sublink.
Default: DISABLE
Select in accordance with the
requirements of your specific
application