Table D-6. Download Configuration Parameters
Parameter Function Values Configuration Guidelines
DNLOAD
MODE
Selects the inband
transmission mode for
the selected link.
NONE – Inband SNMP and Telnet
traffic is ignored and FCD-E1LC does
not generate such traffic.
TS0/F – Inband SNMP and Telnet
traffic is received and transmitted in
timeslot 0.
FRAME_RL – Inband SNMP and
Telnet traffic is received and
transmitted in a dedicated,
user-selected timeslot, using the
Frame Relay protocol.
Default: NONE
After changing the download
mode from FRAME_RL to
TS0/F and vice versa, you
must reset the FCD-E1LC to
make the changes in
management effective (use
the RESET command).
TS NUM
Selects the dedicated
timeslot used for the
selected link.
Any number in the range of 1
through 31, consistent with the
available timeslots and the link
framing mode.
Default: 1
This parameter is displayed
only when the Frame Relay
mode is selected
SPEED
Selects the data rate
used to transfer inband
management traffic for
the selected link.
Always 64 kbps This parameter is displayed
only when the Frame Relay
mode is selected.
SA4
Controls the handling of
the national bit Sa4.
MGMT The S
a4
bit is used to carry
inband management traffic.
ZERO The S
a4
bit is set to “0” before
it is transferred to the S
a4
bit of the
external E1 interface.
ONE
Same as above, except the
Sa4 bit is set to “1”.
Default:
ONE
When the INB_MNG
parameter is TS0/F, at least
one of the bits must be set
to MGMT.
SA5
Controls the handling of
the national bit Sa5 by
the corresponding port
Same options as for SA4
SA6
Controls the handling of
the national bit Sa6 by
the corresponding port
Same options as for SA4
SA7
Controls the handling of
the national bit Sa7 by
the corresponding port
Same options as for SA4
SA8
Controls the handling of
the national bit Sa8 by
the corresponding port
Same options as for SA4