Specifications
Installation and Operation Manual Appendix D Supervision Terminal Commands
FCD-E1LC Ver. 1.0 Commands D-7
procedure until all the alarms in the selected group have been defined. After
the last alarm, you will see again the date and time, followed by the working
prompt.
DEF AR
Purpose
Control the use of SNMP traps for alarms reporting.
Syntax
DEF AR
Use
1. To configuration the use of traps for alarm reporting, type:
DEF AR<Enter>
FCD-E1LC displays the alarm data form.
ALARM REPORT
MAJOR ON NO
2. To display the next row, press <Enter>. A typical data form, as seen after all
the rows have been displayed, is shown below:
ALARM REPORT
MAJOR ON YES
MAJOR OFF YES
MINOR ON YES
MINOR OFF YES
The data form lists the relevant alarm conditions, and the action to be taken
for each alarm condition. The following fields appear on the data form:
ALARM The reported condition:
MAJOR ON A new major alarm condition has been detected.
MAJOR OFF The major alarm condition disappears.
MINOR ON A new minor alarm condition has been detected.
MINOR OFF The minor alarm condition disappears.
REPORT The response to the corresponding condition:
YES – the corresponding alarm condition is reported by means of
a trap sent to management stations.
NO – the corresponding alarm does not result in a trap.
3. To change the current selections, bring the cursor to the desired field, and
then press the <F> or <B> keys to display the desired selection (YES or NO).
When done, press <Enter> to end.