Specifications

Installation and Operation Manual Quick Start Guide
FCD-E1LC Ver. 1.0 Configuration Using a Supervisory Terminal 3
Configuration Procedure
Perform the following actions in the order given below.
Step Action Use the Command
1 Reset the database to the default parameters
INIT DB
2 Define the terminal control codes
DEF TERM
3 Configure the supervisory port
DEF SP
DEF CALL
4 Set FCD-E1LC system time and date
TIME
DATE
5 Configure management access and system parameters
DEF SYS
DEF AGENT
DEF MANAGER LIST
DEF ROUTE
6 Configure the main link parameters
DEF ML
7 Configure the sub link parameters (optional)
DEF SL
8 Configure the data channel parameters
DEF CH 1
DEF CH 2 (when installed)
9 Configure system timing
DEF SYS
10 Define the general system parameters
DEF NAME
DEF NODE
DEF PWD
11 Define the alarm handling parameters
DEF AR
DEF ALM MASK
FCD-E1LC is now ready for operation.